Why Regular Fire Alarm Inspections are Important

Discover the importance of fire alarm inspections, their benefits, and how to conduct them effectively.

A safety officer conducting an internal fire alarm inspection

What is a Fire Alarm Inspection?

A fire alarm inspection refers to the comprehensive evaluation of the fire alarm system, ensuring they are fully operational and compliant with safety regulations. This involves examining various components, such as sensors, control panels, and warning devices, so the system can alert occupants in case of a fire and enable in-house safety teams to respond effectively.

Why Inspecting Fire Alarms is Important

Regular fire alarm system inspections are a critical aspect of fire safety management. Conducting this ensures the following:

  • Verifies system functionality – Checking the fire alarm system components as often as weekly and hiring third-party experts to conduct comprehensive inspections semi-annually ensures it works as intended.
  • Identifies issues early – Regular inspection also detects potential problems, such as broken wiring, battery faults, and degradation due to extreme temperature and humidity. This reduces the occurrence of false alarms that may lead to complacency and prevents system failures, which could prove to be disastrous.
  • Compliance with regulations – Inspection and testing of fire alarm systems are governed by country and state regulations. In the United States, the Occupational Safety and Health Administration (OSHA) and the National Fire Protection Association (NFPA) mandate regular checks to meet workplace safety standards.

Ensure Health & Safety Compliance with Ease

Stay ahead of regulations and maintain a safe workplace with a digitized compliance tool.

Explore our Health & Safety Compliance Solution

When is a Fire Alarm Inspection Done?

Inspecting fire alarm systems should be done regularly, depending on local fire codes and regulations. This frequency guide shows how often the checks should be done and what should be looked at:

  • Weekly – Visual inspections of control equipment, alarm components, and batteries
  • Monthly – More detailed inspections, including battery and signaling device testing
  • Quarterly – Testing of initiating devices, such as air aspirating detectors, heat and smoke sensors, and fire sprinklers, to name a few
  • Semi-annually to annually – In-depth inspections of fire alarm panels, strobes, fire doors, extinguishers, and elevators, particularly done by licensed technicians

How Does One Conduct Fire Alarm Inspections?

A fire alarm inspection involves several key steps to ensure the system’s functionality and compliance with safety standards. Here’s a breakdown of what’s typically involved:

Step 1: Visual Inspection

The first step involves examining all visible components of the system and checking for signs of damage, wear, and tampering. Here are some must-dos:

  • Conduct visual inspections weekly for proactive risk identification.
  • Clean the components of dust and debris, which can impair their functionality.
  • Use comprehensive checklists to ensure that nothing is overlooked during the inspection.

 

Create your own Fire Inspection checklist

Build from scratch or choose from our collection of free, ready-to-download, and customizable templates.

Browse Fire Inspection checklists

Step 2: Functional Testing

The next step involves activating the system components to ensure they operate correctly, especially in an actual fire event.

  • Review the system manual to ensure that every detector, alarm, and manual pull station is tested.
  • Simulate real conditions, such as using smoke or heat, to ensure functionality.
  • Notify building occupants before testing to ensure a smooth process and prevent panic.

Step 3: Control Panel Evaluation

The control panel is the heart of the fire alarm system, so checking its functionality, display, and communication with other devices is crucial. Most conventional control panels share the same parts and interface, but it’s vital to commission a technician who knows the system well.

  • Check error codes or alerts that may indicate issues.
  • Ensure wiring and connections are intact and secure.
  • Update the control panel’s software to acquire the latest features and improvements.

Step 4: Battery Check

Since the battery is the system’s backup supply in case of a power outage, ensuring its functionality is important to maintain safety at all times.

  • Test the battery twice a year to ensure it still holds a charge.
  • Replace the batteries when needed and, more importantly, according to manufacturer recommendations.
  • Check and clean terminals or change them in case of corrosion to ascertain good connection.

Step 5: Documentation and Reporting

The findings, deficiencies, and corrective actions should be documented to provide a clear history of the system’s condition and maintenance. In addition to that, the reports generated during the checks are one of the most important fire alarm inspection requirements when it comes to compliance.

  • Use a standardized reporting form for consistency, accuracy, and completeness of information.
  • Keep a detailed log of all inspections done, storing them in a centralized repository for easy access.
  • Regularly review documentation to identify and proactively manage recurring issues.

Common Issues Found During Inspections

In-house inspectors and third-party technicians should be prepared for problems that usually arise when they do routine checks or in-depth system evaluations so that they can implement preventive controls and corrective actions.

Some of the most prevalent problems identified during fire alarm inspections include the following:

  • Battery failures – This is the most common issue noted by inspectors. Hence, companies should have a ready supply of backup power units to maintain system operability.
  • System malfunctions – Faulty wiring, sensor malfunctions, and control panel errors are common observations during inspections.
  • Aging equipment – Aside from the fact that everything goes through wear and tear, older systems won’t function as reliably as the new ones. Organizations should be ready to replace components if reconditioning isn’t possible.
  • Environmental factorsDust, dirt, and extreme temperatures can affect the performance of fire alarm components. Aside from cleaning the components, investing in environmental sensors may help ensure that sensitive equipment and electronics are kept in optimal temperature and humidity.
  • Improper placement of fire detection equipment – Smoke and heat detectors should be properly positioned and unobstructed since these are critical for early warning and timely response. Manual pulls should also be visible to everyone in the facility. Including these little tidbits during fire safety training can help prevent this problem.

How Long Does a Fire Alarm Inspection Take?

Weekly visual checks of the system don’t take long. Security and maintenance teams can even include this during their rounds or add it to their daily task list. On the other hand, detailed inspections may last from three hours to a day, depending on the facility’s size and system complexity.

Conducting the latter may take long. However, everyone should remember that a properly functioning fire alarm system can detect fires early. This is the key to avoiding injuries, preventing loss of life, and minimizing property damage.

Eunice Arcilla Caburao
Article by

Eunice Arcilla Caburao

SafetyCulture Content Contributor
Eunice Caburao is a content contributor for SafetyCulture. A registered nurse, theater stage manager, Ultimate Frisbee athlete, and mother, she has written a wide range of topics for over a decade. Eunice draws upon her rich, multidisciplinary background to create informative articles about emerging topics on health, safety, and workplace efficiency.